T or F: Because the enriching section of a distillation column has higher concentrations of the less volatile product in it, it tends to be the cooler portion of a distillation system.

1 / 70

Tags and Description

71 Terms

1

T or F: Because the enriching section of a distillation column has higher concentrations of the less volatile product in it, it tends to be the cooler portion of a distillation system.

False

New cards
2

T or F: For a distillation column, the lower the reflux ratio, the lower the utility costs for proper operation.

True

New cards
3

T or F: In a typically used industrial distillation column, the liquid surface is boiling violently and is well mixed which is not true for the vapor phase.

True

New cards
4

Distillation is possible only of the solution components are ___ a. volatile b. non-volatile c. cryogenic d. none of the mentioned

volatile

New cards
5

If the vapor pressure of the two components in a binary mixture is same, then it is a _____ a. isotope b. azeotrope c. differential boiling point d. none of the mentioned

azeotrope

New cards
6

The use of vapor produced from the reboiler is ____ a. to strip out more volatile component from liquid b. to strip out less volatile component from the liquid c. to increase the temperature of the fractionator bottom d. none of the mentioned

to strip out more volatile component from liquid

New cards
7

The reflux of liquid produced from the condenser is ___ a. to strip out more volatile component from vapor b. to strip out less volatile component from the vapor c. to decrease the temperature of the fractionator top d. none of the mentioned

to strip out less volatile component from the vapor

New cards
8

The light key components are ____ a. more volatile b. less volatile c. non volatile d. none of the mentioned

more volatile

New cards
9

The heavy key components are ____ a. more volatile b. less volatile c. non volatile d. none of the mentioned

less volatile

New cards
10

If the feed enters the distillation column at its dew point, then the slope of the feed line is _____ a. infinity b. 0 c. 1 d. between 0 and 1

0

New cards
11

If the feed enters the distillation column at its boiling point, then the slope of the feed line is ____ a. infinity b. 0 c. 1 d. between 0 and 1

infinity

New cards
12

What is the location of the condenser in the figure? a. P b. R c. S d. no condenser

P

<p>P</p>
New cards
13

At total reflux, a. residue is 0 b. distillate is 0 c. reflux is 0 d. all of the mentioned

distillate is 0

New cards
14

The point where the operating line and the equilibrium line meet in distillation methods is known as ___ a. plait point b. Q point c. pinch point d. none of the mentioned

pinch point

New cards
15

Gilliland Correlation is arranged to estimate the ___ a. numbers of stages b. numbers of reboiler c. numbers of feed d. numbers of column

numbers of stages

New cards
16

Once the components are identified, in a multicomponent distillation they are called ___ a. key components b. mixed components c. flow components d. gain components

key components

New cards
17

Raising the column pressure results in ____ a. lower relative volatility b. higher relative volatility c. no effect d. decreased throughput

lower relative volatility

New cards
18

At minimum reflux, number of stages is a. unity b. infinite c. minimized d. negative

infinite

New cards
19

In a binary system, the higher the concentration of the less volatile species in the feed to a flash drum: a. the higher the liquid flow rate leaving the drum b. the higher the vapor flow rate leaving the drum c. the larger the flash drum d. cannot determine

The higher the liquid flow rate leaving the drum

New cards
20

The value of Ki can be expressed as: a. yj/xi b. yi/xj c. xi/yi d. yi/xi

yi/xi

New cards
21

The relative volatility of components i and k can be defined as: a. Ki/Kj b. K/Kj c. yi/y d. xi/x

Ki/Kj

New cards
22

The energy balance around a distillation column is given by: a. FhF + Qc + Qr = DhD + BhB b. FhF - Qc + Qr = DhD + BhB c. V1H1 + Qc = L0h0 + DhD d. V1H1 - Qc = L0h0 + DhD

FhF + Qc + Qr = DhD + B*hB

New cards
23

The material balance around the condenser is given by: a. F = D - B b. F = D + B c. V = L + D d. V = L - D

V = L + D

New cards
24

The reflux ratio can be defined as: a. V/L b. D/L c. V/B d. L/D

L/D or L0/d

New cards
25

The slope of the top operating line in distillation is: a. V/L b. L/V c. Vbar/Lbar d. Lbar/Vbar

L/V

New cards
26

The intercept of the bottom operating line in distillation is: a. Lbar/Vbar b. Vbar/Lbar c. 1 - Lbar/Vbar d. 1 + Lbar/Vbar

1 - Lbar/Vbar

New cards
27

HETP stands for: a. height of efficient total packing b. height equivalent to theoretical plate c. height expected to product d. high energy thermal plasma

height equivalent to theoretical plate

New cards
28

Column diameter is most dependent on: a. tray type used b. reboiler duty c. liquid velocity d. vapor velocity

vapor velocity

New cards
29

Which of the following is used when determining tray spacing? a. propensity of liquid to foam/entrain b. need for person to access top of trays c. a&b d. none of the above

propensity of liquid to foam/entrain need for person to access top of trays

New cards
30

The phenomena of the flowing liquid toward the wall of tower and dispersed in lateral direction is called ___ a. channeling b. flow casting c. entraining d. regimens

channeling

New cards
31

As a rule of thumb, the overall efficiency is: a. 0.1 to 0.3 b. 0.3 to 0.5 c. 0.5 to 0.7 d. 0.7 to 0.9

0.5 to 0.7

New cards
32

When sizing a column, switching for trays to packing usually results in: a. increased height b. decreased height c. no change in height d. no change in trend

decreased height

New cards
33

The higher the concentration of volatile species in the feed to a flash drum: a. the higher the liquid flow rate b. the higher the vapor flow rate c. the larger the flash drum d. cannot determine

the higher the vapor flow rate

New cards
34

The overall material balance for a flash drum is: a. F = V - L b. F = V/L c. F = V + L d. F = F * L

F = V + L

New cards
35

For multi-component flash distillation, the equation used for iterative solving is the a. Michaelis-Menten b. Monod c. Van der Waals d. Rachford-Rice

Rachford-Rice

New cards
36

The overall material balance for a distillation column is: a. F = D - B b. F = D + B c. V = L + D d. V = L - D

F = D + B

New cards
37

When heat is supplied to bottom of liquid stage to vaporize a portion, it is called: a. condensing b. boil-up c. cooling d. desalting

boil-up

New cards
38

When a portion of the overhead product is returned to the column, it is called: a. reflux b. dew point c. boil-up d. relative BP

reflux

New cards
39

The energy balance around the condenser is given by: a. FhF + Qc + Qr = DhD + BhB b. FhF - Qc + Qr = DhD + BhB c. V1H1 + Qc = L0h0 + DhD d. V1H1 - Qc = L0h0 + DhD

V1H1 + Qc = L0h0 + D*hD

New cards
40

The quality of feed represents: a. The fraction of liquid in the feed b. The fraction of vapor in the feed c. The apparent fraction of liquid in the feed d. The apparent fraction of vapor in the feed

The apparent fraction of liquid in the feed

New cards
41

The fraction of the feed represents: a. The fraction of liquid in the feed b. The fraction of vapor in the feed c. The apparent fraction of liquid in the feed d. The apparent fraction of vapor in the feed

The apparent fraction of vapor in the feed

New cards
42

Which of the following is NOT necessarily true for Constant Molar Overflow? a. the volume flows are constant b. the molar flows are constant c. the heat of vaporization is constant between stages d. the heat capacity is constant between stages

the volume flows are constant

New cards
43

Total reflux condition at steady-state means that: a. D = 0 b. B = 0 c. F = 0 d. all of the above

D = 0, B = 0, F = 0

New cards
44

Minimum reflux is the point where: a. reflux is zero b. bottoms flow is maximized c. the separation can be completed with an infinite number of stages d. reflux = distillate

the separation can be completed with an infinite number of stages

New cards
45

process of separating components based on differences in volatility

distillation

New cards
46

product of a distillation separation containing the majority of the more volatile components coming from the top of the unit

distillate

New cards
47

the product of a distillation separation containing the majority of the less volatile components coming from the bottom of the unit

bottoms

New cards
48

the ratio of the condensed overhead vapor flow that is returned to the column vs the amount that is taken off as product (L/D)

reflux ratio

New cards
49

Order the following from most volatile to least volatile: propane i-pentane n-pentane methane

methane propane i-pentane n-pentane

New cards
50

What are the two state variables you can adjust in flash distillation to change the composition of the product streams?

drum pressure and feed temperature

New cards
51

What are the four flow regimes possible in distillation?

bubble, foam, froth, and spray

New cards
52

For the light key component, equilibrium relation is a .yK=x b. Kx=y c. depend upon trays d. cannot be specified

Kx=y

New cards
53

If the fractional recovery of light key in the distillate is FR, then the light key in the feed is a. DxD=(FRD)+FxLK b. DxD=(FRD)-FxLK c. DxD=(FRD)FxLK d. DxD=(FRD)

DxD=(FRD)FxLK

New cards
54

For multi-component systems, Fenske Method gives a. minimum reflux b. minimum strip c. maximum reflux d. minimum trays

minimum trays

New cards
55

For multi-component systems, Underwood Equations gives a. minimum reflux b. minimum strip c. maximum reflux d. minimum trays

minimum reflux

New cards
56

The component balance of the more volatile component is given as a. FzF=DxD+BxB b. FzF=DxD-BxB c. FzF=DxD/BxB d. FzF=DxD*BxB

FzF=DxD+BxB

New cards
57

A pinch point may occur at intersection of feed line and a. stream line b. stripping line c. rectifying line d. equilibrium line

equilibrium line

New cards
58

The real number of trays are obtained as a ratio of a. number of ideal trays and flow rate b. number of ideal trays and efficiency c. number of ideal trays and reflux ratio d. number of ideal trays and stripping ratio

number of ideal trays and efficiency

New cards
59

Which of the following is an important assumption of McCabe Thiele method? a. heat loss is maximum b. heat loss is negligible c. heat loss is infinite d. cannot be specified

heat loss is negligible

New cards
60

Which is a proper form of Henry's Law? a. Ptot=Hbxb b. yb=Hbxb c. yb=Hb/xb d. Pb=Hb*xb

Pb=Hb*xb

New cards
61

Which is represented by the figure? a. stripper b. scrubber c. heat exchanger d. three-phase extractor

scrubber

<p>scrubber</p>
New cards
62

Which is represented by the figure? a. stripper b. scrubber c. heat exchanger d. three-phase extractor

stripper

<p>stripper</p>
New cards
63

A scrubber is designed to a. remove contaminant from liquid phase b. remove contaminant from gas phase c. separate two liquids d. dissolve solid in gas phase

remove contaminant from gas phase

New cards
64

A stripper is designed to a. remove contaminant from liquid phase b. remove contaminant from gas phase c. separate two liquids d. dissolve solid in gas phase

remove contaminant from liquid phase

New cards
65

How many trays are represented in the drawing? a. 0 b. 1 c. 2 d. 3

2

<p>2</p>
New cards
66

If the fractional recovery of light key in the distillate if FR,D, then the amount of light key in the distillate is

FR,D-Fz,LK FR,D+Fz,LK FR,DFz,LK

FR,DFz,LK

New cards
67

Place these in order of least to most expensive separation structure

Random packing Bubble cap Structured packing Valve tray Sieve tray

Sieve tray Valve tray Bubble cap Random packing Structured packing

New cards
68

Column height depends on

number of trays tray type reboiler duty reflux ratio

number of trays

New cards
69

Column diameter is most dependent on

tray type used reboiler duty liquid velocity vapor velocity

vapor velocity

New cards
70

Operating velocity should be ____ flooding velocity

greater than less than equal to

less than

New cards
71

Packed columns are generally

taller and thinner shorter and thinner taller and wider shorter and wider

shorter and thinner

New cards

Explore top notes

note Note
studied byStudied by 33 people
Updated ... ago
5.0 Stars(2)
note Note
studied byStudied by 10 people
Updated ... ago
5.0 Stars(2)
note Note
studied byStudied by 19 people
Updated ... ago
5.0 Stars(1)
note Note
studied byStudied by 6 people
Updated ... ago
4.0 Stars(1)
note Note
studied byStudied by 1 person
Updated ... ago
5.0 Stars(1)
note Note
studied byStudied by 10569 people
Updated ... ago
4.9 Stars(50)
note Note
studied byStudied by 7 people
Updated ... ago
5.0 Stars(1)
note Note
studied byStudied by 10 people
Updated ... ago
5.0 Stars(1)

Explore top flashcards

flashcards Flashcard199 terms
studied byStudied by 7 people
Updated ... ago
5.0 Stars(1)
flashcards Flashcard30 terms
studied byStudied by 9 people
Updated ... ago
5.0 Stars(1)
flashcards Flashcard37 terms
studied byStudied by 23 people
Updated ... ago
5.0 Stars(3)
flashcards Flashcard30 terms
studied byStudied by 7 people
Updated ... ago
5.0 Stars(2)
flashcards Flashcard73 terms
studied byStudied by 13 people
Updated ... ago
5.0 Stars(1)
flashcards Flashcard123 terms
studied byStudied by 16 people
Updated ... ago
5.0 Stars(1)
flashcards Flashcard45 terms
studied byStudied by 38 people
Updated ... ago
5.0 Stars(1)
flashcards Flashcard53 terms
studied byStudied by 3460 people
Updated ... ago
4.2 Stars(54)